Spezial-Hochspannungskabel

Special cable includes multiconductor types in many different configurations. Customer applications often demand for specific solutions, e.g. the transmission of low voltage signals on high voltage potential, transmission of high frequency power signals pulsed power applications or exotic environmental conditions.

hivolt.de is able to offer modified standard types or full custom designs for applications where special cable types are required. We provide solutions.


Type Overview

RATED
VOLTAGE
TYPE
 
DESCRIPTION
 
CONDUCTORS DIELECTRIC
MATERIAL
JACKET
MATERIAL
OUTER
DIA
STA-
TUS
[kVDC] [kVAC] # [AWG] [mm] *1
0.25 HSC‑0.25‑8Q1SFA‑6 low capacitance, multiconductor 8 28 PTFE-E Tape FEP 15.8 E
1 HSC-1-2SSUB-0 HF, power 2 10 SILICONE TPE-U 15.1 S
1 HSC-1-4SSUA-6 HF, power 4 11 SILICONE TPE-U 18.7 S
3 HSC-3-2A1SAB-0 MV measurement 2 EVA EVA 19.0 S
3 HSC-3-2S1SSB-0 signal/power on HV 2 18 SILICONE SILICONE 9.4 E
7.5 3 HSC-7.5-2K2SA radiation resistant pump cable 2 22 PEEK V2A BRAID 5.0 S
8 2.5 HSC-2.5-7SSB-2 HV insulated control cable 7 26 FEP SILICONE 9.0 E
9 106331 shielded with additional LV wire 1
1
23
20
PE PVC 1.6 S
10 HSC-10-6SSSA multiconductor 6 20 SILICONE SILICONE 14.1 E
15 2181-1 outer shield 2
2
6
20
SILICONE PVC 20.3 E
15 2183 outer shield 3 8 SILICONE NEOPRENE 18.5 E
15 2201 outer shield 2
2
10
20
SILICONE PVC 13.7 E
15 2207 outer shield 2
2
4
20
SILICONE PVC 22.9 E
15 2211-R1 outer shield 2
2
8
20
SILICONE PVC 15.8 E
15 5 HSC-5-7X2SVA-2 HV insulated control cable 7 26 PP / PE PVC 10.6 E
21 15 HSC-15-2SSA-9 signal/power on HV 2 17 SILICONE SILICONE 19.5 S
30 2187 outer shield 3 20 SILICONE TPR 13.5 E
30 HSC-30-3S2SUC-0 double shield 3 14
20
SILICONE TPE-U 23.5 E
30 HSC-30-9SSC-2 unshielded 8
1
22
12
SILICONE SILICONE 19.1 E
40 2176 outer shield 4 18 SILICONE PVC 19.0 E
50 2111 outer shield 4 16 SILICONE NEOPRENE 24.1 E
50 2188 outer shield 5 16 SILICONE PVC 24.6 E
50 2228 inner shields 3 16 SILICONE PVC 21.1 E
60 2233 outer shield 19 18 PE PVC 30.5 E
*1 - The preferred cable types have status P. Please refer to the Cable Terminology page for complete list of status designators.

Sample Cross Section Views


Disclaimer

The information given here is technical data, not assured product characteristics. It has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. The user has to ensure by adequate tests that the product is suitable for his application regarding safety and technical aspects.
hivolt.de GmbH & Co. KG does not assume any liability arising out of the application or use of any product described.

Safety Advice

Design, installation and inspection of machinery and devices carrying high voltage require accordingly trained and qualified personnel. Appropriate safety rules and directives must be complied with.
Improper handling of high voltage can mean severe injuries or death and may cause serious collateral damage!