Output up to 10kV up to 9W

Features

high-voltage-supply HMM
  • HMM series in very small compact box
  • Precision high voltages up to 10 kV at max. 9 W
  • Polarity positive or negative, factory fixed
  • Stable output voltage
  • Low ripple and noise
  • Very low EMI
  • Patented resonance converter technology
  • Internal reference voltage
  • High voltage output by HV connector or HV cable
  • INHIBIT input
  • Remote control and monitoring of V and I
  • Modified versions on request

The HMM series includes high voltage power supply modules with output voltages up to 10 kV in a very compact and easily mountable housing.
The maximum power is 9 W, the polarity is factory fixed. The HV output is finished by a SHV connector (KINGS for 10 kV) or by a HV cable. The supply and control voltages are connected via a D-Sub 9 connector. An internal reference voltage can be used to control the output voltage with help of an external potentiometer. Analog I/O is provided for remote monitoring and control of output voltage and current. The patented resonance converter technology and the metal box shielding guarantee lowest EMI.

Model Overview

Output Voltage Output Current Model Ripple
VO IO Positive Polarity Output Negative Polarity Output (f > 10 Hz)
0 – 0.5 kV 15 mA HMM-0.5P15-24-*1 HMM-0.5N15-24-*1 10 mVp-p
0 – 1 kV 8 mA HMM-1P8-24-*1 HMM-1N8-24-*1 10 mVp-p
0 – 2 kV 4 mA HMM-2P4-24-*1 HMM-2N4-24-*1 10 mVp-p
0 – 3 kV 3 mA HMM-3P3-24-*1 HMM-3N3-24-*1 10 mVp-p
0 – 4 kV 2 mA HMM-4P2-24-*1 HMM-4N2-24-*1 10 mVp-p
0 – 6 kV 1 mA HMM-6P1-24-*1 HMM-6N1-24-*1 30 mVp-p
0 – 8 kV 1 mA HMM-8P1-24-*1 HMM-8N1-24-*1 30 mVp-p
0 – 10 kV 0.5 mA HMM-10P0.5-24-*1 HMM-10N0.5-24-*1 30 mVp-p

*1 - Specify HV output variant: "R" for SHV or KINGS connector, "W" for HV cable,
eg. HMM-0.5P15-24-R

The standard output implementation for 0.5kV – 6kV units is a SHV connector, the 8kV and 10kV units are equipped with a shielded HV cable. Other versions are available on request; minimum order quantity may apply.

Disclaimer

The information given here is technical data, not assured product characteristics. It has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. The user has to ensure by adequate tests that the product is suitable for his application regarding safety and technical aspects.
hivolt.de GmbH & Co. KG does not assume any liability arising out of the application or use of any product described.

Safety Advice

Design, installation and inspection of machinery and devices carrying high voltage require accordingly trained and qualified personnel. Appropriate safety rules and directives must be complied with.
Improper handling of high voltage can mean severe injuries or death and may cause serious collateral damage!