Special High Voltage Cable
Special cable includes multiconductor types in many different configurations. Customer applications often demand for specific solutions, e.g. the transmission of low voltage signals on high voltage potential, transmission of high frequency power signals pulsed power applications or exotic environmental conditions.
hivolt.de is able to offer modified standard types or full custom designs for applications where special cable types are required. We provide solutions.
Type Overview
RATED VOLTAGE |
TYPE |
DESCRIPTION |
CONDUCTORS | DIELECTRIC MATERIAL |
JACKET MATERIAL |
OUTER DIA |
STA- TUS |
[kVDC] | [kVAC] | # | [AWG] | [mm] | *1 |
---|---|---|---|---|---|---|---|---|---|
0.25 | HSC‑0.25‑8Q1SFA‑6 | low capacitance, multiconductor | 8 | 28 | PTFE-E Tape | FEP | 15.8 | E | |
1 | HSC-1-2SSUB-0 | HF, power | 2 | 10 | SILICONE | TPE-U | 15.1 | S | |
1 | HSC-1-4SSUA-6 | HF, power | 4 | 11 | SILICONE | TPE-U | 18.7 | S | |
3 | HSC-3-2A1SAB-0 | MV measurement | 2 | EVA | EVA | 19.0 | S | ||
3 | HSC-3-2S1SSB-0 | signal/power on HV | 2 | 18 | SILICONE | SILICONE | 9.4 | E | |
7.5 | 3 | HSC-7.5-2K2SA | radiation resistant pump cable | 2 | 22 | PEEK | V2A BRAID | 5.0 | S |
8 | 2.5 | HSC-2.5-7SSB-2 | HV insulated control cable | 7 | 26 | FEP | SILICONE | 9.0 | E |
9 | 106331 | shielded with additional LV wire | 1 1 |
23 20 |
PE | PVC | 1.6 | S | |
10 | HSC-10-6SSSA | multiconductor | 6 | 20 | SILICONE | SILICONE | 14.1 | E | |
15 | 2181-1 | outer shield | 2 2 |
6 20 |
SILICONE | PVC | 20.3 | E | |
15 | 2183 | outer shield | 3 | 8 | SILICONE | NEOPRENE | 18.5 | E | |
15 | 2201 | outer shield | 2 2 |
10 20 |
SILICONE | PVC | 13.7 | E | |
15 | 2207 | outer shield | 2 2 |
4 20 |
SILICONE | PVC | 22.9 | E | |
15 | 2211-R1 | outer shield | 2 2 |
8 20 |
SILICONE | PVC | 15.8 | E | |
15 | 5 | HSC-5-7X2SVA-2 | HV insulated control cable | 7 | 26 | PP / PE | PVC | 10.6 | E |
21 | 15 | HSC-15-2SSA-9 | signal/power on HV | 2 | 17 | SILICONE | SILICONE | 19.5 | S |
30 | 2187 | outer shield | 3 | 20 | SILICONE | TPR | 13.5 | E | |
30 | HSC-30-3S2SUC-0 | double shield | 3 | 14 20 |
SILICONE | TPE-U | 23.5 | E | |
30 | HSC-30-9SSC-2 | unshielded | 8 1 |
22 12 |
SILICONE | SILICONE | 19.1 | E | |
40 | 2176 | outer shield | 4 | 18 | SILICONE | PVC | 19.0 | E | |
50 | 2111 | outer shield | 4 | 16 | SILICONE | NEOPRENE | 24.1 | E | |
50 | 2188 | outer shield | 5 | 16 | SILICONE | PVC | 24.6 | E | |
50 | 2228 | inner shields | 3 | 16 | SILICONE | PVC | 21.1 | E | |
60 | 2233 | outer shield | 19 | 18 | PE | PVC | 30.5 | E |
*1 - | The preferred cable types have status P. Please refer to the Cable Terminology page for complete list of status designators. |
Sample Cross Section Views
Disclaimer
The information given here is technical data, not assured product characteristics. It has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. The user has to ensure by adequate tests that the product is suitable for his application regarding safety and technical aspects.
hivolt.de GmbH & Co. KG does not assume any liability arising out of the application or use of any product described.
Safety Advice
Design, installation and inspection of machinery and devices carrying high voltage require accordingly trained and qualified personnel. Appropriate safety rules and directives must be complied with.
Improper handling of high voltage can mean severe injuries or death and may cause serious collateral damage!